Ozone Test Chamber AH38040

Ozone Test Chamber is used for testing and judging the rubbers’ ozone resistance aging property when they’re in the static stretching or continuous dynamic tensile deformation or continuous dynamic and static stretching alternate tensile deformation according to the crack and other properties’ change occurred on the sample’s surface.

Temperature range

RT-60℃

Humidity deviation

≤65% R.H

Heating rate

0.7-1℃/Min

Time set range

0-999H

Ozone concentration

50-500PPM

Details About Ozone Test Chamber AH38040

Applicable scope:

Schools, factories, military industry, research department, etc.

Standard:

GB/T 7762-2003

GB/T 2951.21-2008

Technical parameters:

  • Temperature range: RT-60℃
  • Temperature fluctuation: ±0.5℃
  • Temperature deviation: ≤±2℃
  • Humidity deviation: ≤65% R.H
  • Humidity uniformity: +2%-3% R.H
  • Heating rate: 0.7-1℃/Min
  • Time set range: 0-999H
  • Ozone concentration: 50-500PPM
  • Gas Flow Rate: 12-16mm/s
  • Sample rack running speed: 1R/Min (adjustable)
  • Fixture elongation: 5%-35%
  • Working size (Customers’ self choice)
Working volumeWorking dimension (mm)
100L400*500*500
150L500*600*500
225L500*600*750
500L700*800*900
800L800*1000*1000
1000L1000*1000*1000
1300L1000*1000*1300

Specification:

  • Overall dimension: According to customers’ choice.
  • Power: According to customers’ choice.